Simultaneous Thermal Analyzer (STA) combines TGA (Thermogravimetric Analysis) with DTA
(Differential Thermal Analysis) or DSC (Differential Scanning Calorimetry), in which we can get
the information of TG and DTA or DSC in synchrony using the same sample during the same
operation.
STA-500 Simultaneous Thermal Analyzer Overview
Simultaneous Thermal Analyzer (STA) measures DSC and TGA simultaneously in a single unit.
It allows the investigation of Thermogravimetric (TG) effects coupled with the recording of a Differential Scanning Calorimetry (DSC) heat flow signal.
Simultaneous Thermal Analyzer (STA) is an analytical instrument used to measure the heat flow associated with material transitions as a function of temperature. It is widely utilized in various industries and research fields for thermal analysis. Here are some key application areas:Oxidation induction time (OIT),Glass transition (Tg),Melt,Crystal,Thermal stability,Curing /crosslinking,Cold crystal,Phase transition
Standards:
ISO/TR10837:1991, ASTM D3895-1998, ASTM E 967, ASTM E 968,
ASTM E 793, ASTM D 3895, ASTM D 3417, ASTM D 3418, ISO 11357-6 ETC...
◪ The furnace body is heated by double-row winding of precious metal nickel-cadmium alloy wire, which reduces interference and is more resistant to high temperatures.
◪
The tray sensor is made of precious metal alloy wire, which has the advantages of high temperature resistance, oxidation resistance and corrosion resistance.
◪
The power supply and circulating heat dissipation part are separated from the main machine to reduce the influence of heat and vibration on the micro-thermal balance.
◪
Adopt top-opening structure, easy to operate. It is difficult to move the furnace body up to place the sample, and it is easy to damage the sample rod.
◪
The host uses the heat insulation of the heating furnace body to the chassis and micro-thermal balance.
◪
The furnace body can be replaced according to customer requirements.
Model | STA-500 | |
Temperature range | RT ~ 1550℃ | |
Temperature resolution | 0.01℃ | |
Temperature fluctuation | ±0.1℃ | |
Heating rate | 1~100℃/min | |
Constant Temperature Time | 0~300min, settable | |
Cooling time | 15min (1000~100℃) | |
Weighing Range | 0.01mg~3g (Can be extended to 30g) | |
DSC Measure Range | 0~±600mW | |
Weighing Accurate | 0.01mg |
Polymer Industry test | √ |
Pharmaceutical Industry test | √ |
Food Industry test | √ |
Chemical Industry test | √ |
Materials Science test | √ |
Textile Industry test | √ |
Environmental Science test | √ |
Academic Research test | √ |
Aerospace and Automotive Industries test | √ |
Cosmetics Industry test | √ |
Recommended
They are all manufactured according to the strictest international standards. Our products have received favor from both domestic and foreign markets.
They are now widely exporting to 200 countries.