DSC is designed to determine the inner heat transition relating to temperature and heat flow, it is widely used in the field of polymer development, performance testing & quality control.
DSC-300C Differential Scanning Calorimeter Overview
DSC research and development includes the following field: glass transition temperature, melting point, cold crystallization, crystallization, phase transition, oxidation induction time (OIT).
Differential Scanning Calorimeter (DSC) is an analytical instrument used to measure the heat flow associated with material transitions as a function of temperature. It is widely utilized in various industries and research fields for thermal analysis. Here are some key application areas:Oxidation induction time (OIT),Glass transition (Tg),Melt,Crystal,Thermal stability,Curing /crosslinking,Cold crystal,Phase transition
Standards:
ISO/TR10837:1991, ASTM D3895-1998, ASTM E 967, ASTM E 968,
ASTM E 793, ASTM D 3895, ASTM D 3417, ASTM D 3418, ISO 11357-6 ETC...
◪ The industrial-grade 7-inch touch screen displays rich information.
◪
Brand-new metal furnace body structure, with better baseline and higher accuracy. The heating adopts indirect conduction method, which has high uniformity and stability, reduces pulse radiation, and is better than traditional heating mode.
◪
USB communication interface, strong versatility, reliable and uninterrupted communication, supports self-recovery connection function.
◪
Automatically switch the two-channel atmosphere flow, fast switching speed and short stabilization time. At the same time, a protective gas input is added.
◪
Mechanical cooling via low temperature thermostatic bath, better controlled with good linear curve. It can be reused to save costs than liquid nitrogrn.
DSC Range | 0~± 800mW | |
Temperature Range | -40 ~ 600℃ | |
Heating Rate | 0.1~100℃/min | |
Cooling Rate | 0.1~20℃/min | |
Constant Temperature Time | Program set ≤ 24h | |
Temperature Resolution | 0.01℃ | |
Temperature Fluctuation | ±0.01℃ | |
Temperature Repeatability | ±0.1℃ | |
Temperature Control Mode | Rising Temp, Constant Temp, Cooling Temp (Full Automatic Programmed Control) | |
Curve Scanning | Rising Scan + Cooling Scan | |
Atmosphere Control Gas | Nitrogen, Oxygen (Switch Automatically) | |
Thermocouples | Total 3 sets of thermocouples for: 1). Test Sample Temperature 2). Test Furnace Temperature, 3). Test Internal Ambient Temperature |
Polymer Industry test | √ |
Pharmaceutical Industry test | √ |
Food Industry test | √ |
Chemical Industry test | √ |
Materials Science test | √ |
Textile Industry test | √ |
Environmental Science test | √ |
Academic Research test | √ |
Aerospace and Automotive Industries test | √ |
Cosmetics Industry test | √ |
Recommended
They are all manufactured according to the strictest international standards. Our products have received favor from both domestic and foreign markets.
They are now widely exporting to 200 countries.